Description
Chemtron GC Zero Air Generators are designed to supply ultrapure hydrocarbon-free zero air for GC-FID applications. Catalytic oxidation technology eliminates hydrocarbons to <0.1ppm, resulting in a flat, stable baseline, increased sensitivity, and repeatable analysis.
GC Zero Air features:
* Flow rate from 1.5 to 30 l/min
* Pressure up to 6.5 bar (95 psig)
* Zero air purity <0.1ppm HC
* Minimal maintenance
* 2-year standard warranty
OPERATING PRINCIPLE
Zero Air Generators use three steps to transform ambient air into analytical grade air.
STEP 1: PRE-FILTRATION
An external oil-free compressor delivers air through a high-efficiency filter that traps any particles that may damage the system. The filter, which has an automatic purge system, traps oil, water, and any particles larger than 5 microns in size.
STEP 2: HC AND CO TRAPPING
The air leaving the filter enters a high-temperature platinum catalyzer, which eliminates hydrocarbon molecules down to < 0.1 ppm through oxidation.
STEP 3: FINAL FILTRATION
A final pass through a high-efficiency filter prevents any kind of particles from entering the instrument.
BENEFITS
BETTER DETECTOR PERFORMANCE
The reduction of carbon monoxide and hydrocarbons (including methane) to < 0.1 ppm decreases the background noise level and gives the baseline much better stability, increasing detector sensitivity considerably, and ensuring precise analytical results.
EASY INSTALLATION
Just connect a suitable oil-free compressor (optional). To save bench space, the unit can be easily wall-mounted.
LAB SAFETY
No more bottles in the lab and expensive pipelines for air distribution.
SAVE MONEY
All that the unit requires is a connection to a suitable oil-free compressor and the mains. Typically the investment is recovered in less than a year.
IMPROVED LAB EFFICIENCY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and avoiding the need for tedious instrument recalibrations.
Models | GC1500 | GC3000 | GC6000 | GC15000 | GC30000 |
Flow ( L/min ) | 1.5 | 3 | 6 | 15 | 30 |
Weight ( kg ) | 5 | 9 | 12 | 22 | 22 |
HC & CO out | < 0.1 | ||||
Max CO in | 50 ppm | ||||
Max HC in | 100 ppm | ||||
Max temp. in | 40 ℃ | ||||
Pressure in | 4.5-10 bar | ||||
Pressure drop | <1 bar | ||||
Stability ( min ) | 45 | ||||
In / out connections | 1/4-1/8 ( NPT ) | ||||
Power | 110-120V 60Hz / 220-240V 50Hz | ||||
Dimensions ( mm ) | 410H×550W×230D | ||||
Working temp | Amb.+15℃ | ||||
Certification | CE, CSA, FCC |
Models | GT1500 | GT3000 | GT6000 | GT15000 | GT30000 |
Flow ( L/min ) | 1.5 | 3 | 6 | 15 | 30 |
Weight ( kg ) | 9 | 9 | 25 | 25 | 25 |
Dimensions ( mm ) | 410H×550W×250D | 410H×550W×250D | 410H×550W×250D | 470H×630W×310D | 470H×630W×310D |
HC & CO out | < 0.1 ppm | ||||
CO2 out | < 5 ppm | ||||
NOX, SOX out | < 0.1 ppm | ||||
Max CO in | 50 ppm | ||||
Max HC in | 100 ppm | ||||
Max temp. in | 40℃ | ||||
Pressure in | 4.5-10 bar | ||||
Pressure drop | < 1 bar | ||||
Stability ( min ) | 45 | ||||
In / out connections | 1/4-1/8 ( NPT ) | ||||
Power | 110-120V 60Hz / 220-240V 50Hz | ||||
Working temp | Amb.+15℃ | ||||
Certification | CE, CSA, FCC |